A galvanized square fan offers the airflow plants, humans and equipment need with efficient sizing and energy use. The high air velocity of these box fans provides the maximum cooling effect for the lowest electrical cost. They’re perfect for cooling plants and animals, controlling insects, drying bedding or creating a comfortable work environment for your employees.
We’ll help you find the best box fan for commercial or DIY applications. Our fans feature and 18-gauge galvanized housing, heavy-duty venturi frames and blades, balanced high-output blades and removable screens for easy cleaning. With box fan sizes ranging from small 24-inch fans to a 50-inch large box fan, plus a choice of three or six blades and 115/230V or 230/460V power, the right fan is available with a Low Price Guarantee. See the full specifications below along with how to calculate the correct box fan CFM for your structure.
Available in 24-inch, 36-inch and 50-inch models.
Select your desired fan model from the drop-down box at the top right of the page. Sizing information is below.
| Part No. | Size | HP | Volt | Amps | HZ | Phs | Thrust CFM | Noise | RPM | Blade |
|---|---|---|---|---|---|---|---|---|---|---|
| VG24DM | 24″ | 1/2 | 115/230 | 4.8/2.4 | 60 | 1 | 5000 | 62/56 | 847 | 3-Alm |
| VG36DM | 36″ | 1/2 | 115/230 | 6.1/3.0 | 60 | 1 | 9650 | 66 | 845 | 3-Galv |
| VG36VF36GBM | 36″ | 1/2 | 115/230 | 6.6/3.3 | 60 | 1 | 9800 | 65 | 572 | 4-Galv |
| VG36VF36 | 36″ | 1 | 115/230 | 9.0/4.5 | 60 | 1 | 13540 | 65 | 786 | 4-Galv |
| VG50 | 50″ | 1 | 115/230 | 9.0/4.5 | 60 | 1 | 21200 | 68 | 585 | 3-Galv |
| VG503 | 50″ | 1 | 230/460 | 3.2/1.6 | 60 | 3 | 21500 | 68 | 586 | 3-Galv |
| VG503CA | 50″ | 1 | 230/460 | 3.2/1.6 | 60 | 3 | 21700 | 68 | 586 | 3-CA |
| VG50CA | 50″ | 1 | 115/230 | 9.0/4.5 | 60 | 1 | 21800 | 68 | 583 | 3-CA |
DD – Direct Drive, BD – Belt Drive, CA – Cast Aluminum
1. The first thing that you need to determine is the amount of air required. This is stated in CFM (Cubic Feet of air per Minute).
2. Use the following formula to determine the CFM required for your greenhouse:
CFM = Length x Width x Height
Example: Greenhouse 12′ wide x 24′ long x 12′ high requires 3,456 CFM (12 x 24 x 12 = 3,456)
3. Reference the above table. Select the appropriate combination of fan(s) to achieve the necessary CFM rating. Be sure to match the total CFM output for your exhaust fan(s) to the CFM ratings for your Inlet Shutters.
Click here to view fan installation detail